IG4000 Action _ Rev 1.1


NC / NO / Polarity

  • Set-up for Power Off Status
    • NC (Normal Close) – maintain switch connection
    • NO (Normal Open) – maintain switch disconnection

*Definitions according selection of connecting ports


  • Set-up for Operation on Power On Status
    • Polarity – Settled signal for initial status and operation status
    • Delay Time – Keep open for a settled time after authentication, turn back to after settled time pass

*Definitions according to set with special setting card


  • Table by Door Action

 

POLARITY

 

1

0

 

LOCK

NO

NC

Generally Power On standby status is closed

UNLOCK

NC

NO

Door Open status during fixed time


  • Table by Connecting Port

 Port

Polarity 1

Polarity 0

Stand by status

Control

 Stand by status

Control

NC

Open

Connect

Connect

Open

NO

Connect

Open

Open

Connect

*Connection=On
*Open=Off


  • IG4000 Default Setting
    • Polarity: 0
    • Delay Time: 3000 msec



Scenario 1 (Emergency exit_1)

  • Lock
    • Lock keep being opened in case Control Wires are Opened (Disconnected)
  • Scenario (Emergency Exit)
    • Door power off - Unlock
    • Stand by status - Lock
    • Door Authentication - Unlock for a while
  • Install & connect
    • Connect to NO port of IG4000
    • Polarity : 1




Scenario 1 (Emergency exit_2)

  • Lock
    • Lock keep being opened in case Control Wires are Closed (Connected)
  • Scenario (Emergency Exit)
    • Door power off - Unlock
    • Stand by status - Lock
    • Door Authentication - Unlock for a while
  • Install & connect
    • Connect to NC port of IG4000
    • Polarity : 1




Scenario 2 (Common Facilities)

  • Facilities Type
    • Lock keep being opened in case Control Wires are Opened (Disconnected)
  • Scenario
    • Door power off - Lock
    • Stand by status - Lock
    • Door Authentication - Unlock for a while
  • Install & connect
    • Connect to NC port of IG4000
    • Polarity : 0



Scenario 3 (Storage)

  • Lock
    • Lock keep being opened in case Control Wires are Closed (Connected)
  • Scenario (Storage)
    • Door power off - Lock
    • Stand by status - Lock
    • Door Authentication - Unlock for a while
  • Install & connect
    • Connect to NO port of IG4000
    • Polarity : 0


Scenario 4 (Elevator all floors)


  • Product : Elevator Button Control
    • Button push action in case Button Common Signal Wire is Closed (Connected)
  • Scenario (Elevator Button)
    • Power off - button is activated
    • In stand by status - button isn’t activated
    • Authentication - Button is activated for a while
  • Install & connect
    • Connect to NC port of IG4000
    • Polarity : 1



Door Lines Connection




Elevator Lines Connection


  • Generally elevator has 2 buttons: up and down
  • There are 2 lines for each of the button, totally 4 lines and two of them should to be connected into the common IG4000 should be connected with this common button line


Pin Name

Abbreviation

Explanation

Pin 1

+12V

 DC 12V power connect

Pin 2

GND

 GND

Pin 3

TMN_T

Door open Switch input Tx Data (Option)

Pin 4

TMN_R

Rx Data (Option)

Pin 5

NO

Normally Open Terminal

Pin 6

COM

Relay Common Terminal

Pin 7

NC

Normally Closed Terminal